Semi- and virtual 3D dosimetry in clinical practice

Stine Korreman

    Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

    Abstract

    In this review, 3D dosimetry is divided in three categories; "true" 3D, semi-3D and virtual 3D. Virtual 3D involves the use of measurement arrays either before or after beam entry in the patient/phantom, whereas semi-3D involves use of measurement arrays in phantoms mimicking the patient. True 3D involves the measurement of dose in a volume mimicking the patient.There are different advantages and limitations of all three categories and of systems within these categories. Choice of measurement method in a given case depends on the aim of the measurement, and examples are given of verification measurements with various aims
    Original languageEnglish
    Title of host publication7th International Conference on 3D Radiation Dosimetry
    Volume444
    PublisherIOP Publishing
    Publication date2013
    EditionConference 1
    DOIs
    Publication statusPublished - 2013
    Event7th International Conference on 3D Radiation Dosimetry (IC3DDose) - Sydney , Australia
    Duration: 4 Nov 20128 Nov 2012
    http://www.ipem.ac.uk/Portals/0/Documents/Conferences/Conference%20Reports/7th%20International%20Conference%20on%203D%20Radiation%20Dosimetry%20(IC3DDose),.pdf

    Conference

    Conference7th International Conference on 3D Radiation Dosimetry (IC3DDose)
    CountryAustralia
    CitySydney
    Period04/11/201208/11/2012
    Internet address
    SeriesJournal of Physics: Conference Series (Online)
    ISSN1742-6596

    Cite this

    Korreman, S. (2013). Semi- and virtual 3D dosimetry in clinical practice. In 7th International Conference on 3D Radiation Dosimetry (Conference 1 ed., Vol. 444). IOP Publishing. Journal of Physics: Conference Series (Online) https://doi.org/10.1088/1742-6596/444/1/012007
    Korreman, Stine. / Semi- and virtual 3D dosimetry in clinical practice. 7th International Conference on 3D Radiation Dosimetry . Vol. 444 Conference 1. ed. IOP Publishing, 2013. (Journal of Physics: Conference Series (Online)).
    @inproceedings{75e2919f3ef4406ca2d3811623b699d2,
    title = "Semi- and virtual 3D dosimetry in clinical practice",
    abstract = "In this review, 3D dosimetry is divided in three categories; {"}true{"} 3D, semi-3D and virtual 3D. Virtual 3D involves the use of measurement arrays either before or after beam entry in the patient/phantom, whereas semi-3D involves use of measurement arrays in phantoms mimicking the patient. True 3D involves the measurement of dose in a volume mimicking the patient.There are different advantages and limitations of all three categories and of systems within these categories. Choice of measurement method in a given case depends on the aim of the measurement, and examples are given of verification measurements with various aims",
    author = "Stine Korreman",
    year = "2013",
    doi = "10.1088/1742-6596/444/1/012007",
    language = "English",
    volume = "444",
    booktitle = "7th International Conference on 3D Radiation Dosimetry",
    publisher = "IOP Publishing",
    edition = "Conference 1",

    }

    Korreman, S 2013, Semi- and virtual 3D dosimetry in clinical practice. in 7th International Conference on 3D Radiation Dosimetry . Conference 1 edn, vol. 444, IOP Publishing, Journal of Physics: Conference Series (Online), Sydney , Australia, 04/11/2012. https://doi.org/10.1088/1742-6596/444/1/012007

    Semi- and virtual 3D dosimetry in clinical practice. / Korreman, Stine.

    7th International Conference on 3D Radiation Dosimetry . Vol. 444 Conference 1. ed. IOP Publishing, 2013. (Journal of Physics: Conference Series (Online)).

    Research output: Chapter in Book/Report/Conference proceedingArticle in proceedingsResearchpeer-review

    TY - GEN

    T1 - Semi- and virtual 3D dosimetry in clinical practice

    AU - Korreman, Stine

    PY - 2013

    Y1 - 2013

    N2 - In this review, 3D dosimetry is divided in three categories; "true" 3D, semi-3D and virtual 3D. Virtual 3D involves the use of measurement arrays either before or after beam entry in the patient/phantom, whereas semi-3D involves use of measurement arrays in phantoms mimicking the patient. True 3D involves the measurement of dose in a volume mimicking the patient.There are different advantages and limitations of all three categories and of systems within these categories. Choice of measurement method in a given case depends on the aim of the measurement, and examples are given of verification measurements with various aims

    AB - In this review, 3D dosimetry is divided in three categories; "true" 3D, semi-3D and virtual 3D. Virtual 3D involves the use of measurement arrays either before or after beam entry in the patient/phantom, whereas semi-3D involves use of measurement arrays in phantoms mimicking the patient. True 3D involves the measurement of dose in a volume mimicking the patient.There are different advantages and limitations of all three categories and of systems within these categories. Choice of measurement method in a given case depends on the aim of the measurement, and examples are given of verification measurements with various aims

    U2 - 10.1088/1742-6596/444/1/012007

    DO - 10.1088/1742-6596/444/1/012007

    M3 - Article in proceedings

    VL - 444

    BT - 7th International Conference on 3D Radiation Dosimetry

    PB - IOP Publishing

    ER -

    Korreman S. Semi- and virtual 3D dosimetry in clinical practice. In 7th International Conference on 3D Radiation Dosimetry . Conference 1 ed. Vol. 444. IOP Publishing. 2013. (Journal of Physics: Conference Series (Online)). https://doi.org/10.1088/1742-6596/444/1/012007