Semi- and virtual 3D dosimetry in clinical practice

Stine Korreman

    Publikation: Bidrag til bog/antologi/rapportKonferencebidrag i proceedingsForskningpeer review

    Resumé

    In this review, 3D dosimetry is divided in three categories; "true" 3D, semi-3D and virtual 3D. Virtual 3D involves the use of measurement arrays either before or after beam entry in the patient/phantom, whereas semi-3D involves use of measurement arrays in phantoms mimicking the patient. True 3D involves the measurement of dose in a volume mimicking the patient.There are different advantages and limitations of all three categories and of systems within these categories. Choice of measurement method in a given case depends on the aim of the measurement, and examples are given of verification measurements with various aims
    OriginalsprogEngelsk
    Titel7th International Conference on 3D Radiation Dosimetry
    Vol/bind444
    ForlagIOP Publishing
    Publikationsdato2013
    UdgaveConference 1
    DOI
    StatusUdgivet - 2013
    Begivenhed7th International Conference on 3D Radiation Dosimetry (IC3DDose) - Sydney , Australien
    Varighed: 4 nov. 20128 nov. 2012
    http://www.ipem.ac.uk/Portals/0/Documents/Conferences/Conference%20Reports/7th%20International%20Conference%20on%203D%20Radiation%20Dosimetry%20(IC3DDose),.pdf

    Konference

    Konference7th International Conference on 3D Radiation Dosimetry (IC3DDose)
    LandAustralien
    BySydney
    Periode04/11/201208/11/2012
    Internetadresse
    NavnJournal of Physics: Conference Series (Online)
    ISSN1742-6596

    Citer dette

    Korreman, S. (2013). Semi- and virtual 3D dosimetry in clinical practice. I 7th International Conference on 3D Radiation Dosimetry (Conference 1 udg., Bind 444). IOP Publishing. Journal of Physics: Conference Series (Online) https://doi.org/10.1088/1742-6596/444/1/012007
    Korreman, Stine. / Semi- and virtual 3D dosimetry in clinical practice. 7th International Conference on 3D Radiation Dosimetry . Bind 444 Conference 1. udg. IOP Publishing, 2013. (Journal of Physics: Conference Series (Online)).
    @inproceedings{75e2919f3ef4406ca2d3811623b699d2,
    title = "Semi- and virtual 3D dosimetry in clinical practice",
    abstract = "In this review, 3D dosimetry is divided in three categories; {"}true{"} 3D, semi-3D and virtual 3D. Virtual 3D involves the use of measurement arrays either before or after beam entry in the patient/phantom, whereas semi-3D involves use of measurement arrays in phantoms mimicking the patient. True 3D involves the measurement of dose in a volume mimicking the patient.There are different advantages and limitations of all three categories and of systems within these categories. Choice of measurement method in a given case depends on the aim of the measurement, and examples are given of verification measurements with various aims",
    author = "Stine Korreman",
    year = "2013",
    doi = "10.1088/1742-6596/444/1/012007",
    language = "English",
    volume = "444",
    booktitle = "7th International Conference on 3D Radiation Dosimetry",
    publisher = "IOP Publishing",
    edition = "Conference 1",

    }

    Korreman, S 2013, Semi- and virtual 3D dosimetry in clinical practice. i 7th International Conference on 3D Radiation Dosimetry . Conference 1 udg, bind 444, IOP Publishing, Journal of Physics: Conference Series (Online), 7th International Conference on 3D Radiation Dosimetry (IC3DDose), Sydney , Australien, 04/11/2012. https://doi.org/10.1088/1742-6596/444/1/012007

    Semi- and virtual 3D dosimetry in clinical practice. / Korreman, Stine.

    7th International Conference on 3D Radiation Dosimetry . Bind 444 Conference 1. udg. IOP Publishing, 2013.

    Publikation: Bidrag til bog/antologi/rapportKonferencebidrag i proceedingsForskningpeer review

    TY - GEN

    T1 - Semi- and virtual 3D dosimetry in clinical practice

    AU - Korreman, Stine

    PY - 2013

    Y1 - 2013

    N2 - In this review, 3D dosimetry is divided in three categories; "true" 3D, semi-3D and virtual 3D. Virtual 3D involves the use of measurement arrays either before or after beam entry in the patient/phantom, whereas semi-3D involves use of measurement arrays in phantoms mimicking the patient. True 3D involves the measurement of dose in a volume mimicking the patient.There are different advantages and limitations of all three categories and of systems within these categories. Choice of measurement method in a given case depends on the aim of the measurement, and examples are given of verification measurements with various aims

    AB - In this review, 3D dosimetry is divided in three categories; "true" 3D, semi-3D and virtual 3D. Virtual 3D involves the use of measurement arrays either before or after beam entry in the patient/phantom, whereas semi-3D involves use of measurement arrays in phantoms mimicking the patient. True 3D involves the measurement of dose in a volume mimicking the patient.There are different advantages and limitations of all three categories and of systems within these categories. Choice of measurement method in a given case depends on the aim of the measurement, and examples are given of verification measurements with various aims

    U2 - 10.1088/1742-6596/444/1/012007

    DO - 10.1088/1742-6596/444/1/012007

    M3 - Article in proceedings

    VL - 444

    BT - 7th International Conference on 3D Radiation Dosimetry

    PB - IOP Publishing

    ER -

    Korreman S. Semi- and virtual 3D dosimetry in clinical practice. I 7th International Conference on 3D Radiation Dosimetry . Conference 1 udg. Bind 444. IOP Publishing. 2013. (Journal of Physics: Conference Series (Online)). https://doi.org/10.1088/1742-6596/444/1/012007